iVAC 6MBG 6'' Metal Blast Gate. Automated Dust Control
Overview
Blast Gate provides:
Automatic opening and closure of the dust extraction port from a power tool.
When controlled by either a wireless rf connection from an iVAC Pro Product or from a ‘Manual Wired Remote’.
The iVAC Pro Blast Gates are electrically driven Automatic Blast gates.
They are intended to be installed between the dust exhaust of a power tool and the main dust collector ducting to a dust collector.
The Blast Gates are powered from a UL/CSA approved AC to AC adaptor.
There are three methods of controlling the Blast Gate.
a ) Fully Automatic from a power tool on an iVAC Pro System.
When the power tool turns on, the iVAC Pro Tool will issue a wireless command instructing the Blast Gate to open. When the power tool turns off it will instruct the Blast Gate to close.
b ) Wireless Remote from an iVAC Pro Remote.
In this mode an iVAC Pro Remote is used to send the Open and Close commands to the Pro Blast Gate.
c ) Manually Remote from a ‘Manual Wired Remote’
In this mode the operation of the toggle switch on the ‘Manual Wired Remote’ cable will instruct the Blast Gate to open or close.